2014 - Mazda6 - I-ELOOP

PID/DATA MONITOR INSPECTION [i-ELOOP]

1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
a. Select “DataLogger”.
b. Select “Modules”.
c. Select “DCDC”.
3. Select the applicable PID from the PID table.
4. Verify the PID data according to the directions on the screen.

NOTE:



Item

Unit/Condition

description

Condition/Specification (Reference)

BYPS_COUNT

Count of Bypass Relay actuation

  • Displays operation amount of the bypass relay.

BYPS_RLY_STAT1

Low/High

State of Bypass Relay Signal 1

  • Displays the bypass relay signal status.

BYPS_RLY_STAT2

Low/High

State of Bypass Relay Signal 2

  • Displays the bypass relay signal status.

BYPS_STAT

Bypass Off/Bypass On/Bypass Off fault/Bypass On fault

State of Bypass circuit within DC-DC converter

  • Displays the bypass relay status.

    • Bypass relay OFF: Bypass OFF

    • Bypass relay ON: Bypass On

    • Bypass relay OFF(Fail): Off fault

    • Bypass relay ON(Fail): On fault

C_MEAS_END_V

V

DCDC Input Voltage at end of measurement of capacitance at IR

  • Displays the DC-DC converter input voltage when the measurement of the capacitor capacitance is completed.

C_MEAS_STAT

Completion/Incompletion/No directions

State of Electric capacity measurement

  • Displays the measurement status of capacitor capacitance.

    • Measurement completed: Completion

    • Measurement not completed: Incompletion

    • No indication of measurement: No directions

C_MEAS_STR_V

V

DCDC Input Voltage at start of measurement of capacitance at IR

  • Displays the DC-DC converter input voltage when measurement of capacitor capacitance is started.

CHG/DIS_STAT

Off/Charge (to Bat)/Discharge (to GND)/Fault (Off)/Fault (to Bat)/Fault (to GND))

State of charge/discharge circuit within DC-DC converter

  • Displays the charge circuit status.

    • Charge circuit stopped: Off

    • Charged by capacitor and battery: Charge (to Bat)

    • Charged by capacitor and GND: Discharge (to GND)

    • Charge circuit malfunction (charge circuit stopped): Fault (Off)

    • Charge circuit malfunction (charged by capacitor and battery): Fault (to Bat)

    • Charge circuit malfunction (charged by capacitor and GND): Fault (to GND)

CONV_OUT_V

V

Converter circuit Output Voltage

  • Displays the output voltage in voltage reduction circuit.

CONV_STAT

Ready/Power Output(Stop)/Power Output(Normal)/Power Output(Limit)/Safe Mode/Error

State of Converter circuit within DC-DC converter

  • Displays the voltage reduction circuit operation status.

    • Preparation for voltage reduction completed: Ready

    • Output stopped: Power Output(Stop)

    • During output: Power Output(Normal)

    • Target output value not achieved due to limit: Power Output(Limit)

    • Self-protection status (voltage reduction circuit inoperable): Safe Mode

    • Voltage reduction circuit malfunction: Error

CAPA_TEMP

°C, °F

Capacitor (i-ELOOP) temperature

  • Displays the capacitor (i-ELOOP) temperature.

DCDC_IN_V

V

DCDC Input Voltage (Input Terminal Voltage)

  • Displays the DC-DC converter input voltage.

DCDC_OUT_I

A

DCDC Output Current

  • Displays the DC-DC converter output current.

DCDC_OUT_V

V

DCDC Output Voltage (Output Terminal Voltage)

  • Displays the DC-DC converter output voltage.

DCDC_TEMP

DC-DC converter temperature

  • Displays the DC-DC converter temperature

DEGEN_COUNT

Count of Degeneracy shift

  • Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter.

DEGEN_WARN

Ok/Degeneration warning/Degeneration

Warning of Degeneracy

  • Displays the control status due to high temperature in the DC-DC converter.

IG_STAT

Off/On

State of IG signal input

  • Displays the power supply status from the IG1 relay.

IR_SW_STAT

Connect (On)/Disconnect (Off)/Fault (On)/Fault (Off)

State of IG ON circuit within DC-DC converter

  • Displays the IG ON relay operation status.

    • IG ON relay ON: Connect (On)

    • IG ON relay OFF: Disconnect (Off)

    • IG ON relay ON (Fail): Fault (On)

    • IG ON relay OFF (Fail): Fault (Off)

OUT_M_CUR1

A

Output Mean Current in IG On (last time)

  • Displays the average value of the DC-DC converter output current from the previous time the ignition was switched ON.

OUT_M_CUR2

A

Output Mean Current in IG On (2 times before)

  • Displays the average value of the DC-DC converter output current from the previous 2 times that the ignition was switched ON.

OUT_M_CUR3

A

Output Mean Current in IG On (3 times before)

  • Displays the average value of the DC-DC converter output current from the previous 3 times that the ignition was switched ON.

OUT_M_CUR4

A

Output Mean Current in IG On (4 times before)

  • Displays the average value of the DC-DC converter output current from the previous 4 times that the ignition was switched ON.

OUT_M_CUR5

A

Output Mean Current in IG On (5 times before)

  • Displays the average value of the DC-DC converter output current from the previous 5 times that the ignition was switched ON.

PURGE_RESLT

Charged/Purged/Fault

Result of charge purge on Capacitor after IG Off

  • Displays the purge result of the capacitor electrical charge after the ignition is switched off.

SAFE_M_COUNT

Count of Safe Mode shift

  • Displays the number of times the system switches to safe mode for the DC-DC converter.