DTC U3004:16 [START STOP UNIT]



Description

ACC relay circuit malfunction

Detection condition

  • Start stop unit detects that the ACC monitor voltage of less than 2.5 V for 1 s or more with the ignition switched to ACC or ON (engine off or on).

Fail-safe function

Not applicable

Possible cause

  • ACC relay malfunction

  • ACC relay circuit malfunction

    • Short to ground in wiring harness between MAIN 200 A fuse and ACC relay terminal C

    • IG2 30 A fuse malfunction

    • MAIN 200 A fuse malfunction

    • Open circuit in wiring harness between battery positive terminal and ACC relay terminal C

  • Start stop unit connector or terminal malfunction

  • Short to ground in wiring harness between ACC relay terminal D and start stop unit terminal 1E

  • MIRROR 7.5 A fuse malfunction

  • Open circuit in wiring harness between ACC relay terminal D and start stop unit terminal 1E

  • Start stop unit malfunction


Diagnostic Procedure

Step

Inspection

Action

1

INSPECT ACC RELAY

Yes

Go to the next step.

No

Replace the ACC relay, then go to Step 6.

(See RELAY LOCATION.)

2

INSPECT FOR OPEN CIRCUIT OR SHORT TO GROUND IN ACC RELAY CIRCUIT

Yes

Go to the next step.

No

Inspect the IG2 30 A and MAIN 200 A fuse.

  • If the fuse is burnt out:

    • Refer to the wiring diagram and verify whether or not there is a common connector between MAIN 200 A fuse and ACC relay terminal C.

      • If there is a common connector:
      • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.

      • Repair or replace the malfunctioning part.

        If there is no common connector:
      • Repair or replace the wiring harness which has a short to ground.

      • Replace the fuse.

  • If the fuse is damaged:

    • Replace the fuse.

  • If the fuse is normal:

    • Refer to the wiring diagram and verify whether or not there is a common connector between battery positive terminal and ACC relay terminal C.

      • If there is a common connector:
      • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.

      • Repair or replace the malfunctioning part.

        If there is no common connector:
      • Repair or replace the wiring harness which has an open circuit.

Go to Step 6.

3

INSPECT START STOP UNIT CONNECTOR

Yes

Go to the next step.

No

Repair or replace the connector, then go to Step 6.

4

INSPECT FOR SHORT TO GROUND IN ACC RELAY CIRCUIT
  • Verify that the ACC relay is removed.

  • Verify that the start stop unit connector is disconnected.

  • Inspect for continuity between the following terminals (wiring harness-side) and body ground:

    • ACC relay terminal D

    • Start stop unit terminal 1E

  • Is there continuity?

Yes

Inspect the MIRROR 7.5 A fuse.

  • Refer to the wiring diagram and verify whether or not there is a common connector between ACC relay terminal D and start stop unit terminal 1E.

    • If there is a common connector:
    • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.

    • Repair or replace the malfunctioning part.

      If there is no common connector:
    • Repair or replace the wiring harness which has a short to ground.

    • Replace the fuse.

Go to Step 6.

No

Go to the next step.

5

INSPECT FOR OPEN CIRCUIT IN ACC RELAY CIRCUIT
  • Verify that the ACC relay is removed.

  • Verify that the start stop unit connector is disconnected.

  • Inspect for continuity between ACC relay terminal D (wiring harness-side) and start stop unit terminal 1E (wiring harness-side).

  • Is there continuity?

Yes

Go to the next step.

No

Inspect the MIRROR 7.5 A fuse.

  • If the fuse is damaged:

    • Replace the fuse.

  • If the fuse is normal:

    • Refer to the wiring diagram and verify whether or not there is a common connector between ACC relay terminal D and start stop unit terminal 1E.

      • If there is a common connector:
      • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.

      • Repair or replace the malfunctioning part.

        If there is no common connector:
      • Repair or replace the wiring harness which has an open circuit.

Go to the next step.

6

VERIFY THAT REPAIRS HAVE BEEN COMPLETED

Yes

Repeat the inspection from Step 1.

Go to the next step.

No

Go to the next step.

7

VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?

Yes

Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.

(See DTC TABLE [START STOP UNIT].)

No

DTC troubleshooting completed.