< Previous   Next >

2014 - Mazda6 - Body and Accessories

DTC U2300:64 [BLIND SPOT MONITORING (BSM)]



Description

Configuration data unmatched with instrument cluster

Detection condition

  • Configuration data of the BSM control module and instrument cluster are not matched.

Fail-safe function

  • Blind spot monitoring (BSM) system is stopped.

Possible cause

  • DTCs are stored in the instrument cluster.

    • Instrument cluster configuration not implemented

    • Instrument cluster internal memory malfunction

  • Instrument cluster configuration data error

  • BSM control module malfunction

System wiring diagram

Not applicable


Diagnostic Procedure

Step

Inspection

Action

1

VERIFY INSTRUMENT CLUSTER DTCs

Yes

Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.

(See DTC TABLE [INSTRUMENT CLUSTER].)

No

Go to the next step.

2

RESET INSTRUMENT CLUSTER CONFIGURATION DATA

Yes

Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step.

(See INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA).)

No

Go to Step 4.

3

VERIFY THAT REPAIRS HAVE BEEN COMPLETED

Yes

Repeat the inspection from Step 1.

Go to the next step.

No

Go to the next step.

4

VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?

Yes

Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.

(See DTC TABLE [BLIND SPOT MONITORING (BSM)].)

No

DTC troubleshooting completed.




< Previous   Next >
Back to Top
© 2012 Mazda North American Operations, U.S.A.