< Previous   Next >

2014 - Mazda6 - HVAC

CLIMATE CONTROL UNIT INSPECTION [MANUAL AIR CONDITIONER]

1. Remove the climate control unit with the connector connected. (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].)
2. Switch the ignition ON (engine off or on).
3. Connect the negative (-) lead of the tester to body ground.
4. Insert the positive (+) lead of the tester into each climate control unit terminal and measure the voltage according to the terminal voltage table.

Terminal Voltage Table (Reference)



Terminal

Signal name

Connected to

Measurement condition

Voltage (V)

Inspection item (s)

A

GND

Body ground

Under any condition

1.0 or less

  • Related wiring harness

B

B+

ROOM 15 A fuse

Under any condition

B+

  • Related wiring harness

  • ROOM 15 A fuse

C

D

IG2

Front body control module (FBCM)

Switch the ignition ON (engine off or on)

B+

  • Related wiring harness

  • Front body control module (FBCM)

Switch the ignition off

1.0 or less

E

Blower fan speed control

Blower fan controller

Switch the ignition off

1.0 or less

  • Related wiring harness

  • Blower fan controller

Fan stopped (Switch the ignition ON (engine off or on))

2.5

Fan: manual 1st

3.7

Fan: manual 3rd

6.9

Fan: manual 7th

B+

F

G

+5V

  • Air mix actuator

  • Airflow mode actuator

Under any condition

5

  • Related wiring harness

  • Air mix actuator

  • Airflow mode actuator

  • Climate control unit: terminal voltage (K)

H

Evaporator temperature sensor input

Evaporator temperature sensor

Compared with temperature detected by evaporator temperature sensor

Refer to graph 1

  • Related wiring harness

  • Evaporator temperature sensor

  • Climate control unit: terminal voltage (G)

I

J

Potentiometer input

Airflow mode actuator

VENT

4.3 or more

  • Related wiring harness

  • Airflow mode actuator

  • Climate control unit: terminal voltage (G)

BI-LEVEL

3.4

HEAT

2.5

HEAT/DEF

1.6

DEFROSTER

0.7 or less

K

Sensor GND

  • Air mix actuator

  • Airflow mode actuator

  • Evaporator temperature sensor

Under any condition

1.0 or less

  • Related wiring harness

  • Climate control unit: terminal voltage (G)

L

Potentiometer input

Air mix actuator

Set temperature at MAX HOT

4.3 or more

  • Related wiring harness

  • Air mix actuator

  • Climate control unit: terminal voltage (G)

Set temperature at MAX COLD

1.0 or less

M

N

Motor operation (VENT)

Airflow mode actuator

Moving towards VENT

B+

  • Related wiring harness

  • Airflow mode actuator

Moving towards DEFROSTER

1.0 or less

O

P

Motor operation (DEFROSTER)

Airflow mode actuator

Moving towards DEFROSTER

B+

  • Related wiring harness

  • Airflow mode actuator

Moving towards VENT

1.0 or less

Q

R

Motor operation (FRESH)

Air intake actuator

Moving towards RECIRCULATE

1.0 or less

  • Related wiring harness

  • Air intake actuator

Moving towards FRESH

B+

S

T

Motor operation (RECIRCULATE)

Air intake actuator

Moving towards RECIRCULATE

B+

  • Related wiring harness

  • Air intake actuator

Moving towards FRESH

1.0 or less

U

MS_CAN_H

CAN related module

Because this terminal is for communication, integrity determination by terminal voltage is not possible.

  • Related wiring harness

V

Motor operation (COLD)

Air mix actuator

Moving towards HOT

1.0 or less

  • Related wiring harness

  • Air mix actuator

Moving towards COLD

B+

W

MS_CAN_L

CAN related module

Because this terminal is for communication, integrity determination by terminal voltage is not possible.

  • Related wiring harness

X

Motor operation (HOT)

Air mix actuator

Moving towards HOT

B+

  • Related wiring harness

  • Air mix actuator

Moving towards COLD

1.0 or less







< Previous   Next >
Back to Top
© 2012 Mazda North American Operations, U.S.A.