2014 - Mazda6 - HVAC

BLOWER FAN CONTROLLER REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER]

NOTE:

1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.5].)
2. Remove the following parts:
a. Glove compartment (See GLOVE COMPARTMENT REMOVAL/INSTALLATION.)
b. Dashboard under cover (See DASHBOARD UNDER COVER REMOVAL/INSTALLATION.)
c. Side wall (passenger-side) (See SIDE WALL REMOVAL/INSTALLATION.)
d. Front heat duct (passenger-side) (See FRONT HEAT DUCT REMOVAL/INSTALLATION.)
3. Disconnect the connector.

4. Rotate the blower fan controller (2) while pressing the tab (1).

5. Remove the blower fan controller.

6. Install in the reverse order of removal.