2014 - Mazda6 - HVAC

CLIMATE CONTROL UNIT INSPECTION [FULL-AUTO AIR CONDITIONER]

1. Remove the climate control unit with the connector connected. (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].)
2. Switch the ignition ON (engine off or on).
3. Connect the negative (-) lead of the tester to body ground.
4. Insert the positive (+) lead of the tester into each climate control unit terminal and measure the voltage according to the terminal voltage table.

Terminal Voltage Table (Reference)



Terminal

Signal name

Connected to

Measurement condition

Voltage (V)

Inspection item (s)

1A

GND

Body ground

Under any condition

1.0 or less

  • Related wiring harness

1B

B+

ROOM 15 A fuse

Under any condition

B+

  • Related wiring harness

  • ROOM 15 A fuse

1C

1D

IG1

C/U IG1 15 A fuse

Switch the ignition ON (engine off or on)

B+

  • Related wiring harness

  • C/U IG1 15 A fuse

Switch the ignition off

1.0 or less

1E

Blower fan speed control

Blower fan controller

Switch the ignition off

1.0 or less

  • Related wiring harness

  • Blower fan controller

Fan stopped (Switch the ignition ON (engine off or on))

2.5

Fan: manual 1st

3.7

Fan: manual 3rd

6.9

Fan: manual 7th

B+

1F

IG2

Front body control module (FBCM)

Switch the ignition ON (engine off or on)

B+

  • Related wiring harness

  • Front body control module (FBCM)

Switch the ignition off

1.0 or less

1G

1H

Passenger compartment temperature sensor input

Passenger compartment temperature sensor

Compared with temperature detected by passenger compartment temperature sensor

Refer to graph 1

  • Related wiring harness

  • Passenger compartment temperature sensor

  • Climate control unit: terminal voltage (1N)

1I

1J

Sensor GND

  • Driver-side air mix actuator

  • Passenger-side air mix actuator

  • Airflow mode actuator

  • Evaporator temperature sensor

  • Passenger compartment temperature sensor

Under any condition

1.0 or less

  • Related wiring harness

  • Climate control unit: terminal voltage (1N)

1K

1L

Evaporator temperature sensor input

Evaporator temperature sensor

Compared with temperature detected by evaporator temperature sensor

Refer to graph 2

  • Related wiring harness

  • Evaporator temperature sensor

  • Climate control unit: terminal voltage (1N)

1M

Solar radiation sensor (LH) input

Solar radiation sensor

Sunlight shined directly on solar radiation sensor

4

  • Related wiring harness

  • Climate control unit: terminal voltage (1N)

  • Solar radiation sensor

Blocking light to solar radiation sensor

1.0 or less

1N

+5V

  • Driver-side air mix actuator

  • Passenger-side air mix actuator

  • Airflow mode actuator

  • Solar radiation sensor

Under any condition

5

  • Related wiring harness

  • Driver-side air mix actuator

  • Passenger-side air mix actuator

  • Airflow mode actuator

  • Solar radiation sensor

  • Climate control unit: terminal voltage (1J)

1O

Solar radiation sensor (RH) input

Solar radiation sensor

Sunlight shined directly on solar radiation sensor

4

  • Related wiring harness

  • Climate control unit: terminal voltage (1N)

  • Solar radiation sensor

Blocking light to solar radiation sensor

1.0 or less

1P

1Q

1R*1

Seat warmer switch signal

Seat warmer control unit

Because this terminal is for communication, integrity determination by terminal voltage is not possible.

  • Related wiring harness

  • Seat warmer control unit

1S

MS_CAN_H

CAN related module

Because this terminal is for communication, integrity determination by terminal voltage is not possible.

  • Related wiring harness

1T

1U

MS_CAN_L

CAN related module

Because this terminal is for communication, integrity determination by terminal voltage is not possible.

  • Related wiring harness

1V

1W

1X

2A

Potentiometer input

Airflow mode actuator

VENT

4.3 or more

  • Related wiring harness

  • Airflow mode actuator

  • Climate control unit: terminal voltage (1N)

BI-LEVEL

3.4

HEAT

2.5

HEAT/DEF

1.6

DEFROSTER

0.7 or less

2B

Motor operation (COLD)

Driver-side air mix actuator

Moving towards HOT

1.0 or less

  • Related wiring harness

  • Driver-side air mix actuator

Moving towards COLD

B+

2C

2D

Motor operation (HOT)

Driver-side air mix actuator

Moving towards HOT

B+

  • Related wiring harness

  • Driver-side air mix actuator

Moving towards COLD

1.0 or less

2E

Potentiometer input

Passenger-side air mix actuator

Set temperature at MAX HOT

4.3 or more

  • Related wiring harness

  • Passenger-side air mix actuator

  • Climate control unit: terminal voltage (1N)

Set temperature at MAX COLD

1.0 or less

2F

Motor operation (HOT)

Passenger-side air mix actuator

Moving towards HOT

B+

  • Related wiring harness

  • Passenger-side air mix actuator

Moving towards COLD

1.0 or less

2G

Potentiometer input

Driver-side air mix actuator

Set temperature at MAX HOT

4.3 or more

  • Related wiring harness

  • Driver-side air mix actuator

  • Climate control unit: terminal voltage (1N)

Set temperature at MAX COLD

1.0 or less

2H

Motor operation (COLD)

Passenger-side air mix actuator

Moving towards HOT

1.0 or less

  • Related wiring harness

  • Passenger-side air mix actuator

Moving towards COLD

B+

2I

Motor operation (VENT)

Airflow mode actuator

Moving towards VENT

B+

  • Related wiring harness

  • Airflow mode actuator

Moving towards DEFROSTER

1.0 or less

2J

Motor operation (FRESH)

Air intake actuator

Moving towards RECIRCULATE

1.0 or less

  • Related wiring harness

  • Air intake actuator

Moving towards FRESH

B+

2K

Motor operation (DEFROSTER)

Airflow mode actuator

Moving towards DEFROSTER

B+

  • Related wiring harness

  • Airflow mode actuator

Moving towards VENT

1.0 or less

2L

Motor operation (RECIRCULATE)

Air intake actuator

Moving towards RECIRCULATE

B+

  • Related wiring harness

  • Air intake actuator

Moving towards FRESH

1.0 or less


*1
With seat warmer